HomeProuductsCoaxial Cables

RF 50 LTA Coaxial Cables

Construction

Inner conductor  Tinned copper  7 x 0.25 mm 
Dielectric  Foam PE  Φ2.00 ± 0.10 mm 
Outer conductor (shield 1)  Aluminium+polyester+Al tape 
Shield coverage  100%
Outer conductor (shield 2)  Tinned copper  48 x 0.12 mm 
Shield coverage  64%
Sheath  PVC or LSZH  Φ3.60 ± 0.10 mm 

Electrical & Mechanical Characteristics

Impedance  50±3 Ohm 
Nominal capacitance  95 pF/m 
Velocity of propagation  75%
Insulation resistance  >5000 Mohm.Km 
Inner conductor resistance  20.5 Ohm/Km 
Outer conductor resistance  32.5 Ohm/Km 
Operating temperature range  -30 °C - +70 °C 
Copper weight  8.2 Kg/Km 
Cable weight (approx.)  18.3 Kg/Km 
Screening effectiveness  >75 dB 

Attenuation

Frequency(MHz) 50  Attenuation (dB/100 m) 13.0  Attenuation (dB/100ft) 3.96 
100 17.3 5.27
400 35 10.67
600 43.3 13.2
860 52.7 16.07
1000 57.2 17.44
1750 76.7 23.38
2400 94 28.66

Return Loss

30-300 MHz  >24dB
300-600 MHz  >21dB
600-900 MHz  >15dB